Confirm your Jade 32 lamp configuration before you order

The ProSun Jade 32 was built with two different lamp configurations depending on when the unit was manufactured. That single fact decides which OEM replacement lamp kit you need, so start at the front of your unit and read the exposure label. The label tells you which configuration your bed uses; order only after you have matched it to Kit A or Kit B.

This guide assumes you have already confirmed the correct kit. If you have not, stop here and check the label first. The steps below cover how to change tanning bed lamps once the right ProSun replacement lamps are in hand.

What each ProSun Jade 32 OEM kit contains

  • ProSun Jade 32 - OEM Replacement Lamp Kit: Kit A includes 18 ProTech II Intensive R-UVA 110w 1.9M lamps (3166) and 14 ProTech II Intensive R-UVA 100W lamps (3165). Match this count and model list to the exposure label on your Jade 32 before ordering.

    ProSun Jade 32 - OEM Replacement Lamp Kit

    ProSun Jade 32 - OEM Replacement Lamp Kit

  • ProSun Jade 32 - OEM Replacement Lamp Kit: Kit B includes 18 ProTech II Intensive R-UVA 110w HO 1.9M lamps (3164). The HO lamp model and the absence of the 100W lamps distinguish Kit B from Kit A.

  • ProSun Jade 32 - OEM Replacement Lamp Kit: These are Bi-Pin lamps with a stated life expectancy of 1,000 hours. Bi-Pin bases and the 1,000-hour figure help you plan replacement timing and handle the lamps correctly.

  • ProSun Jade 32 - OEM Replacement Lamp Kit: The kit is listed as home and commercial compatible. This confirms the same OEM kit is intended for both home and commercial Jade 32 units, provided the configuration matches.

Tanning bed lamp replacement steps for a confirmed Jade 32 kit

The supplied product record does not include a manufacturer relamping procedure, so the order below is a practical handling sequence rather than a quoted instruction. Follow your bed manufacturer's service documentation for any bed-specific disassembly or electrical steps.

  1. 1. Match the kit to the exposure label one more time: Before you open the box, compare the kit name and lamp models on the packaging with the exposure label on your Jade 32. Kit A and Kit B are not interchangeable.
  2. 2. Set up a safe, clear work area: Work in a clean space where the Bi-Pin lamps can be laid flat without rolling. Keep the new lamps in their packaging until you are ready to fit each one.
  3. 3. Remove the old lamps in a consistent order: Work from one end of the bed to the other so you do not lose track of which positions have been changed. Handle each lamp by its ends rather than the glass.
  4. 4. Fit the new Bi-Pin lamps: Seat each lamp firmly in its Bi-Pin sockets without forcing it. Confirm the lamp is the same model called for in your kit before moving to the next position.
  5. 5. Check every position before closing up: Count the installed lamps against the kit contents: 18 plus 14 for Kit A, or 18 for Kit B. A missing or mismatched lamp will show up as uneven output.
  6. 6. Record the installation date: The lamps carry a stated 1,000-hour life expectancy. Writing down the install date gives you a reference point for planning the next replacement.

Why the OEM kit matters for a Jade 32

The Jade 32 lamp kit is an OEM replacement set, and the lamp models in each kit are specific to the bed's configuration. The supplied record lists exact ProTech II model numbers for Kit A and Kit B, which is the detail to check when comparing listings. A generic lamp that physically fits the Bi-Pin socket is not the same as the lamp specified for your bed's exposure label.

The record also notes that the kit is economical for the amount of tanning power and can help maximize commercial tanning salon profits. That is a positioning statement from the catalog, not a measured performance claim, so treat it as context rather than a guarantee.

Kit A vs Kit B: the decision that comes first

  • Kit A: 18 ProTech II Intensive R-UVA 110w 1.9M lamps (3166) plus 14 ProTech II Intensive R-UVA 100W lamps (3165). Choose this only if your exposure label matches this configuration.
  • Kit B: 18 ProTech II Intensive R-UVA 110w HO 1.9M lamps (3164). Choose this only if your exposure label matches this configuration.
  • If the label is unclear: The supplied information does not include a fallback method for identifying the configuration without the exposure label. Do not guess between kits; resolve the label question before ordering.

What the supplied information does not settle

The product record does not include a step-by-step relamping procedure, torque values, electrical safety steps, or a disposal method for old lamps. It also does not state a recommended replacement interval beyond the 1,000-hour life expectancy figure. For bed-specific service steps, consult the manufacturer's documentation for your Jade 32.

Absence of those details in the supplied record is not evidence that the manufacturer omits them. It simply means this guide cannot responsibly fill them in.